| Standard Resistance Range & Temperature Coefficients |
|
|
0204 |
0207 |
| ± 0.05% - - A5 |
From
|
100R |
20R |
|
To
|
600K |
1M21 |
| ± 0.10% - - B |
From
|
100R |
20R |
|
To
|
600K |
1M21 |
| ± 0.25% - - C |
From
|
50R |
20R |
|
To
|
800K |
3M |
| ± 0.50% - - D |
From |
10R |
10R |
| To |
1M |
10M |
| ± 1.00% - - F |
From |
10R |
10R |
| To |
1M |
10M |
| ± 5PPM/°C - - C7 |
From |
100R |
100R |
| To |
600K |
1M |
| ± 10PPM/°C - - C6 |
From |
100R |
100R |
| To |
600K |
1M |
| ± 15PPM/°C - - C5 |
From |
50R |
50R |
| To |
600K |
3M |
| ± 25PPM/°C - - C3 |
From |
20R |
20R |
| To |
600K |
3M |
| ± 50PPM/°C - - C2 |
From |
10R |
10R |
| To |
1M |
3M |
|
|
|
|
|
|
Operating temperature of -55°C to 125°C must be dreated at high ambient temperatures according to the curve below.

|
Standard Electrical Specifications
|
|
Type
|
Wattage
@ 70 °C
|
Max. Working
Voltage
|
|
SMC 0204
|
.25
|
200
|
|
SMC 0207
|
.50
|
250
|
|