| product guide | ||||
|
||||
![]() |
||||
| APPLICABLE Mil SPECIFICATIONS: TL series meet or exceed the electrical, mechanical environmental and dimensional requirements of Mil R-26. |
| RESISTANCE TOLERANCE: ± 5% is standard on values above 1 ohm. ±10% is standard on 1 ohm and lower. 3%, 1%, .25% and .05% are also available. |
| CORES: High purity ceramic impervious to moisture will withstand severe thermal shock. |
| COATING: Special high-temperature silicone or ceramic depending on end use. |
| DIELECTRICAL STRENGTH: 1000 VAC minimum for all TL resistors. Available wound inductive or non-inductive. |
| RESISTANCE WIRE: Highest quality copper-nickel-chrome alloy, depending on resistance value. |
| SHORT TIME OVERLOAD: In intermittent usage the applied power can greatly exceed the wattage rating. However, since each pulse is somewhat unique the factory should be contacted for specific requirements. |
| POWER RATING: Power rating is based on (1) 350° C maximum surface temperature in free air. (2) 3% maximum
|
| DERATING: TL types have an operating temperature range of -55° C to +350° C. They must be derated at high ambient temperature according to the curve shown below. |
![]() |
![]() |
| M-O P/N | Length (L) ±.062 |
Dia. O.D. ±.032 |
Dia. I.D. ±.032 |
Wattage Rating | Max. Working Voltage | Resistance Range (ohms) |
| TL-5 | 1.00 | .250 | .156 | 5 | 230 | .1 - 12K |
| TL-10 | 1.00 | .438 | .312 | 10 | 400 | .1 - 22K |
| TL-25 | 2.00 | .563 | .312 | 25 | 1300 | .1 - 100K |
| TL-50 | 4.00 | .563 | .312 | 50 | 1900 | .1 - 250K |
| TL-60 | 4.00 | .750 | .500 | 60 | 2100 | .1 - 350K |
| TL-100 | 6.50 | .750 | .500 | 100 | 2500 | .1 - 550K |
| TL-175 | 8.50 | 1.125 | .750 | 175 | 5000 | .1 - 600K |
| TL-225 | 10.50 | 1.125 | .750 | 225 | 6000 | .1 - 700K |
| Series TL Terminal Dimensions | |||
| M-O P/N |
Width (W) |
Height (H) |
Hole Dia. (h) |
| TL-5 | .125 | .400 | .062 |
| TL-10 | .187 | .408 | .093 |
| TL-25 | .250 | .550 | .154 |
| TL-50 | .250 | .550 | .154 |
| TL-60 | .250 | .750 | .154 |
| TL-100 | .250 | .750 | .154 |
| TL-175 | .530 | .630 | .195 |
| TL-225 | .530 | .630 | .195 |
| Also available with leads welded to lugs (Style TLL) | For non-inductive types add N after part number. |
| ORDERING INFORMATION | ||
| Example: 50w 90 ohm 5% | ||
|
TL50
|
90R0
|
J
|
|
Type
|
Resistance
|
Tolerance
|
| 4 digit. <100 |
K =10
J = 5 G = 2 F = 1 |
|
| TO ORDER PRODUCTS |
| E mail: microohm@vividnet.com |
| Call Toll Free: 1-800-845-5167 |
| home page | product guide | R axial |
FP flat oval |
HS chassis mount | CW bathtub axial | SU bathtub printed circuit | PI radial |
EW edge wound |
RX vitreous axial |
CP bare axial |
RX20 vitreous tubular |